Product Name: Flammable Gas Control and Disposal Device Control the Gas Flow Rate
Product Model: GSL-KR200
Product Description: GSL-KR200 is a combustion gas module to dispose of residual flammable gas via a self-ignition heating coil. It is designed to pair with any SUPSEMI tube and atmosphere furnaces. It can also control the gas flow rate and communicate with a Honeywell hydrogen gas detector. It is a good choice for experiments under a reducing environment, such as hydrogen flow.
Product Description
GSL-KR200 is a combustion gas module to dispose of residual flammable gas via a self-ignition heating coil. It is designed to pair with any SUPSEMI tube and atmosphere furnaces. It can also control the gas flow rate and communicate with a Honeywell hydrogen gas detector. It is a good choice for experiments under a reducing environment, such as hydrogen flow.
Product Parameters
Power | • 200W |
Voltage | • 110V, 208-240VAC, single phase, 50-60Hz |
Features | • Applicable to dispose of various residual flammable gas along the exhaust line (designated gas needs to be discussed with us in advance). • Compact, modularized, and compatible with various SUPSEMI furnaces. • Interlocks: in case of emergency, the gas flow and furnace heating will be cut off. - a flammable gas leak is detected - Failure of a self-ignition heating coil • One check valve to prevent gas backflow. • Two solenoid valve allows users to choose the flow type, inert or flammable. |
Flow rate | • One float flow meter (100-1000 sccm, air) |
Gas Inlets | • Two 1/4" compression tube fittings for both inert and flammable gas. |
Hydrogen Detector System | • The hydrogen gas detector is connected externally. If alarmed, the hydrogen gas and furnace heating function will be cut off. • The alarm is preset at 20% LEL for hydrogen. |
Furnace Dimension | 360L × 340W × 400H (mm) |
Net Weight | 5kg |
Safety WARNING | • If equipped with a tube furnace, a metallic mesh cover must be installed at both ends of the furnace tube in case of emergency. • The furnace and the combustion equipment are recommended to be placed in a well-ventilated place, or in a fume hood. • The hydrogen detector must be installed. • Operators must be trained by qualified technicians & follow the safety guideline of the laboratory. |